MOQ: | 100 pc's |
Prijs: | 2,000 - 5,000 USD per pc |
Standaardverpakking: | Overzeese waardige Verpakking voor het Uitvoeren met Ijzerkader |
Leveringstermijn: | Binnen 90 Dagen na het krijgen van beneden - betaling of L/C |
Betaalmethode: | T/T, L/C bij gezicht |
Toeleveringskapaciteit: | Ongeveer 1.000 ton per maand |
Attribute | Value |
---|---|
Type | Natural Circulation |
Application | boiler maintaince, Boiler Pipe, Heating element |
Material | Stainless steel |
Usage | Industrial, Power Station, Thermal power plant/station boiler |
Color | Customized |
Fuel | Biomass, Waste |
Inspection | ASME Inspection |
Style | Horizontal and Vertical |
Superheater handles saturated steam; reheater processes partially expanded steam.
Use for heating saturated steam, steam temperature could be up to 900 degree C.
Superheater Capacity Upgrades to Increase Power Generation
Send us required technical data, such as steam capacity, pressure, required temperature etc. We will design accordingly.
Type | Advantages | Disadvantages | Supporting method |
---|---|---|---|
Pendant-type | 1. Firm structural support | 1. Flow blockage by condensed steam 2. Needs a slow restart to purge the water that accumulates in the bottom. |
supported from above |
Inverted-type | 1. Proper drainage of the condensed steam | 1. Lack the structural rigidity, especially in high speed gas flow | Supported from below |
Horizontal-type | 1. Proper drainage 2. Good structural rigidity. |
1. They do not view the flame directly so they are mainly from the convective type | Usually supported in the vertical gas ducts parallel to the main furnace. |
![]() |
MOQ: | 100 pc's |
Prijs: | 2,000 - 5,000 USD per pc |
Standaardverpakking: | Overzeese waardige Verpakking voor het Uitvoeren met Ijzerkader |
Leveringstermijn: | Binnen 90 Dagen na het krijgen van beneden - betaling of L/C |
Betaalmethode: | T/T, L/C bij gezicht |
Toeleveringskapaciteit: | Ongeveer 1.000 ton per maand |
Attribute | Value |
---|---|
Type | Natural Circulation |
Application | boiler maintaince, Boiler Pipe, Heating element |
Material | Stainless steel |
Usage | Industrial, Power Station, Thermal power plant/station boiler |
Color | Customized |
Fuel | Biomass, Waste |
Inspection | ASME Inspection |
Style | Horizontal and Vertical |
Superheater handles saturated steam; reheater processes partially expanded steam.
Use for heating saturated steam, steam temperature could be up to 900 degree C.
Superheater Capacity Upgrades to Increase Power Generation
Send us required technical data, such as steam capacity, pressure, required temperature etc. We will design accordingly.
Type | Advantages | Disadvantages | Supporting method |
---|---|---|---|
Pendant-type | 1. Firm structural support | 1. Flow blockage by condensed steam 2. Needs a slow restart to purge the water that accumulates in the bottom. |
supported from above |
Inverted-type | 1. Proper drainage of the condensed steam | 1. Lack the structural rigidity, especially in high speed gas flow | Supported from below |
Horizontal-type | 1. Proper drainage 2. Good structural rigidity. |
1. They do not view the flame directly so they are mainly from the convective type | Usually supported in the vertical gas ducts parallel to the main furnace. |